Firmware availability
No build for this exact model was verified in the site catalog on 22 November 2026. Check the full model and control board before downloading firmware.
See installation optionsFactory rating
| Model | Antminer S23 |
|---|---|
| Hashrate | 305 TH/s |
| Wall power | 3355 W |
| Efficiency | 11 J/TH |
Read the nameplate before choosing firmware
For the air-cooled S23 305T-10, 305 TH/s multiplied by 11 J/TH equals 3355 W. This cross-check catches a misplaced figure in a quotation. An S23 Hyd. has a different cooling system and its own specification. Keep its figures in a separate row.
A field check you can repeat
The same S23 can produce three plausible readings in a shift: instantaneous hashrate in its interface, an average at the pool and power at the distribution unit. Record the start and end of the sample. If the meter also feeds exhaust fans, note their load separately before quoting an efficiency figure for the miner.
Factory specifications and your readings
| Comparison | Basis | Result |
|---|---|---|
| S23 305T-10 | 305 TH/s × 11 J/TH | 3355 W |
| 10 × S23 | 10 × 3355 W | 33.55 kW |
| 100 × S23 | 100 × 3355 W | 335.5 kW |
Sources
As of 22 November 2026
BITMAIN · S23 305T-10BITMAIN · S23 Hyd.

Identify a Z15 at the rack before selecting a file
Why 20 and 20,000 can be the same L11 reading