Why 20 and 20,000 can be the same L11 reading

If an L11 restarted at 10:50, the pool’s 10:00 to 11:00 average includes only ten minutes after the restart. Compare the next full stable interval, convert MH/s to GH/s, then inspect accepted and rejected work before changing settings.

BITMAIN Antminer L11BITMAIN · L11

Firmware availability

No build for this exact model was verified in the site catalog on 22 November 2026. Check the full model and control board before downloading firmware.

See installation options

Factory rating

ModelAntminer L11
Hashrate20 GH/s
Wall power3680 W
Efficiency184 J/GH

Read the nameplate before choosing firmware

For the air-cooled L11 20G, 20 GH/s and 20,000 MH/s describe the same Scrypt throughput. At 25 °C the factory figure is 3680 W, or 184 J/GH. Do not use the power figure of an L11 HU2 to size a row of air-cooled miners.

A field check you can repeat

A pool may record a worker in MH/s while the local L11 dashboard reports GH/s. Convert the units first and align the time windows. Then track the accepted shares and the time since the last restart. A drop in the pool average with a steady local rate calls for a different investigation than a board disappearing from the local dashboard.

Factory specifications and your readings

ComparisonBasisResult
L11 20G20 GH/s × 100020 000 MH/s
L11 20G3680 W ÷ 20 GH/s184 J/GH
L11 20G3.68 kW × 24 h88.32 kWh